How to Reset the PM Counter
3.2 HOW TO RESET THE PM COUNTER
After preventive maintenance work, reset the PM counter (SP7-804) as follows.
3.2.1 D160/D161/D170 MODELS
1. Activate the SP mode (
2. Select SP7-804 (PM Counter Reset).
3. Select SP7-804-002 (60k) or SP7-804-003 (120k).
4. Press the OK key. The message "Execute" shows.
5. Press the button below the message "Execute."
6. The messages "Execute?" followed by "Cancel" and "Execute" show.
7. To reset the PM counter, press the button below the message "Execute."
8. Wait until the message "Completed" shows.
9. Quit the SP mode.
3.2.2 D158/D159 MODELS
1. Activate the SP mode (
2. Select SP7-804 (PM Counter Reset).
3. Select SP7-804-002 (60k) or SP7-804-003 (120k).
4. Press the "Execute" button.
5. Wait until the message "Completed" shows.
6. Quit the SP mode.
D158/D159/D160/D161/D170
p.6-1 "Service Program Mode").
p.6-1 "Service Program Mode").
3-2
SM