User Tool Setting

1. Plug in, and turn the main switch on.
2. Go into the User Tools mode, and select System Settings > Administrator Tools > Detect Data
Security for Copying > "On".
3. Exit the User Tools.
4. Check the operation.
The machine will issue an SC165 error if the machine is powered on with the ICIB-1
removed and the "Detect Data Security for Copying" feature is set to "ON".
When you remove this option from the machine, first set the setting to "OFF" with the
user tool before removing this board. If you forget to do this, "Detect Data Security for
Copying" feature cannot appear in the user tool settings. And then SC165 will appear
every time the machine is switched on, and the machine cannot be used.

2.15.5 FILE FORMAT CONVERTER (D158/D159)

Installation Procedure

Unplug the main machine power cord before you do the following procedure.
1. Remove the card slot cover [A] (
2. Install the file format converter [B] into the board slot and then fasten it with screws.
3. Plug in, and turn the main switch on.
4. Check or set the following SP codes with the values shown below.
D158/D159/D160/D161/D170
x 1).
2-85
Controller Options