GE Range Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Installation Instructions

Range
Questions?
Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com
IN THE COMMONWEALTH OF
MASSACHUSETTS
 This product must be installed by a licensed
plumber or gas fitter.
WARNING
FIRE OR EXPLOSION HAZARD
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or death.
Installation must be performed by a qualified
installer.
Read these instructions completely and carefully.
Installation of this range must conform with
local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/
NFPA.54, latest edition. In Canada, installation
must conform with the current Natural Gas
Installation Code, CAN/CGA-B149.1 or the current
Propane Installation Code, CAN/CGA-B149.2, and
with local codes where applicable. This range
has been design-certified by CSA International
according to ANSI Z21.1, latest edition and
Canadian Gas Association according to CAN/
CGA-1.1 latest edition.
CAUTION -
Only the GE Café branded
series of Advantium® or microwave over-
the-range ovens are designed to be installed
above the GE Café range. Surfaces above a gas
 When using ball type gas shut-off valves, they
shall be the T-handle type.
 A flexible gas connector, when used, must not
exceed 3 feet.
When installing a gas appliance the use of old
flexible connectors can cause gas leaks and
personal injury. Always use a NEW flexible
connector.
Leak testing of the appliance shall be conducted
according to the manufacturer instructions.
The range must be electrically grounded in
accordance with local codes or, in the absence
of local codes, in accordance with the National
Electrical Code (ANSI/NFPA 70, latest edition).
In Canada, electrical grounding must be in
accordance with the current CSA C22.1 Canadian
Electrical Code Part 1 and/or local codes. See
Electrical Connections in this section.
Do not install this product with an air curtain
hood or other range hood that operates by
blowing air down on the cooktop. This airflow
may interfere with operation of the gas burners
resulting in fire or explosion hazard.
range can become hot. Installation of any other
over-the-range oven above a GE Café range
may result in surface temperatures that can
cause burns.
FOR YOUR SAFETY:
WARNING
Tip-Over Hazard
• A child or adult can tip the range and be killed.
• Install the anti-tip bracket to the wall or floor.
• Engage the range to the anti-tip bracket by sliding the
range back such that the foot is engaged.
• Re-engage the anti-tip bracket if the range is moved.
• Failure to do so can result in death or serious burns
to children or adults.
If you did not receive an anti-tip bracket with your
purchase, call 1.800.626.8774 to receive one at no
cost. (In Canada, call 1.800.561.3344.) For installation
instructions of the bracket, visit: www.GEAppliances.com.
(In Canada, www.GEAppliances.ca.)
Anti-Tip Bracket
Kit Included
WARNING
Before beginning
the installation, switch power off at
service panel and lock the service
disconnecting means to prevent power
from being switched on accidentally.
When the service disconnecting means
cannot be locked, securely fasten a
prominent warning device, such as a
tag, to the service panel.

Advertisement

Table of Contents
loading

Summary of Contents for GE Range

  • Page 1: Installation Instructions

    3 feet. Tip-Over Hazard plumber or gas fitter. • A child or adult can tip the range and be killed. • Install the anti-tip bracket to the wall or floor. • Engage the range to the anti-tip bracket by sliding the range back such that the foot is engaged.
  • Page 2: Tools You Will Need

    Drill with 1/8” Bit 4-Wire Cord 4’ long OR future reference. When this range is installed in a mobile home, it 3-Wire Cord 4’ long Servicer – The electrical diagram is in an must be secured to the floor during transit. Any envelope attached to the back of the range.
  • Page 3: Dimensions And Clearances

    Front edge of the range To cabinets side panel below cooktop forward from and at the 0” cabinet range back 0” 1/4” To cabinets below cooktop and at the range back SH 1 of 2 31-10982 C2S985 08-14 GE...
  • Page 4 (OR CONVERTING BACK TO Rear of Range NATURAL GAS FROM LP) This range leaves the factory set for use with natural gas. If you want to convert to LP gas, the conversion must be performed by a qualified LP gas installer.
  • Page 5: Electrical Requirements

    Terminal block the knockout ring (1 ⁄ ”) located on bracket A range cord rated at 40 amps with 125/250 qualified electrician. After installation, have the (appearance directly below the terminal block. To may vary) minimum volt range is required.
  • Page 6 Power Cord The neutral wire and ground strap must be The neutral wire and ground strap must be connected as shown below for the range to be connected as shown below for the range to Ground strap properly grounded. Do not remove the ground be properly grounded.
  • Page 7: Gas Supply

    Make sure everyone operating the range knows where and how to shut off the Installer: Inform the consumer of the location of the gas shut-off valve. WARNING Explosion Hazard: Do not gas supply to the range.
  • Page 8 If glow is not detected within the time limit, recheck the range wiring connections. If range wiring is correct, have building wiring checked for proper connections and voltage. • Be sure all range controls are in the OFF position before leaving the range.
  • Page 9: Para Su Seguridad

    Instrucciones de Instalación Cocina Ante cualquier duda, llame al 1.800-GE-CARES o visite nuestro sitio web en: GEAppliances.com PARA SU SEGURIDAD En el Commonwealth de • Al usar válvulas de cierre de gas tipo balón, deberán ser del tipo de manija T.
  • Page 10: Herramientas Necesarias

    HERRAMIENTAS NECESARIAS MATERIALES NECESARIOS ANTES DE COMENZAR Si se producen fallas en el producto debido a una instalación inadecuada, la Garantía no cubrirá  Válvula de cierre para tubería de gas IMPORTANTE — las mismas. Conserve estas  Sellador para junta de tubería o UL – cinta para instrucciones para uso del inspector de Antes de instalar su cocina sobre linóleo y cualquier Destornillador Philips...
  • Page 11: Dimensiones Y Espacios

    0” gabinete y la parte 0” 1/4” trasera de la Para gabinetes cocina debajo de la parte superior de la cocina y la parte trasera de la cocina SH 1 of 2 31-1098 C2S985 08-14 GE...
  • Page 12 CONVERTIR A GAS LP (o convertir nuevamente a gas Parte Trasera de la Estufa natural de LP) Esta cocina deja la configuración de fábrica para uso con gas natural. Si desea convertir a gas LP, la conversión deberá ser realizada por un instalador de gas LP calificado.
  • Page 13: Requerimientos Eléctricos

    REQUERIMIENTOS ELÉCTRICOS INSTALACIÓN DE CABLE DE ENERGÍA Y DE PASACABLES ADVERTENCIA: Parte trasera de la cocina Esta unidad debe los códigos vigentes puede provocar una situación Acceda al bloque terminal, retirando los contar con una adecuada conexión a tierra. peligrosa. Si no existen códigos locales, su cocina tornillos del cubrecables con una llave de debe contar con cables y fusibles que cumplan con ADVERTENCIA:...
  • Page 14 INSTALACIÓN DE TRES (3) ALAMBRES (LA CONEXIÓN A TIERRA SE INSTALACIÓN DE 4 ALAMBRES (CABLE DE CONEXIÓN A TIERRA REALIZA A TRAVÉS DEL CABLE NEUTRO) SEPARADO) Antes–Cable de energía ADVERTENCIA : Cable de energía ADVERTENCIA : y conducto portacables Riesgo de Descarga Riesgo de Descarga Cinta de El cable neutro y la cinta de conexión a tierra...
  • Page 15 (tubo) como podrá mover una vez realizada la conexión. en la etiqueta de calificación del producto. *Teflón: Marca registrada por DuPont SH 2 of 2 31-10982 C2S985 08-14 GE...
  • Page 16: Dispositivo Antivolcaduras

    Si las llamas del quemador se ven como en (A), CONTROLE LAS CABEZAS DESLICE LA COCINA EN LA ABERTURA llame al servicio técnico. El aspecto de la llama normal se ve como en (B) o (C), dependiendo del DE LOS QUEMADORES A.

Table of Contents