Intrinsically safe humidity and temperature transmitter series (152 pages)
Summary of Contents for Vaisala HUMICAP HMT140
Page 1
QUICK GUIDE Vaisala HUMICAP® Humidity and Temperature Transmitter HMT140 English M211484EN-A...
Page 2
The contents are subject to change without prior notice. Please observe that this manual does not create any legally binding obligations for Vaisala towards the customer or end user. All legally binding commitments and agreements are...
These factory preset quantity selections and other wireless parameters can be changed afterward using the configuration port and included utility if necessary. The HMT140 is available either with a fixed probe directly attached to the transmitter housing or a remote probe with different (3/5/10m) cable lengths.
24mm hole, at a distance of 42mm from each other. 5. Mount the probe holder using the screws (D). 6. Adjust the depth of the plastic pipe and tighten the screw (E) to lock the probe in place. VAISALA _________________________________________________________________...
Status Display Service Power Switch Switch SERVICE CONFIG 3 . 6 a l a t t e Config Cable grommet Header (Rubber plug) Cable bushing: cable gland, cable grommet, Release Tab or conduit fitting Field WireTerminals HMT140 Components _____________________________________________________________ M211484EN-A...
Cable to a USB port on your PC. You can then proceed to configure the utility using the steps below. If you wish to remove the software, you can do so by uninstalling the entry for HMT140 Utility under the publisher Vaisala from the “Programs and Features” or “Add or Remove Programs”...
9. Click the Sensor tab and select a Transmit Period Time and number of tries for the HMT140 if you do not wish to keep the default settings. 10. Click the Update button. The utility will configure the HMT140.
Use the following procedure to trigger a data packet transmission using the IR Sensor: 1. Turn on the HMT140 and wait for the display to turn on then off. 2. Place your hand near the display. The display will turn on again and the beeper will beep.
QUICK GUIDE ______________________________________________________________ Technical Support The complete HMT140 User's Guide is available in English at www.vaisala.com/hmt140 For technical questions, contact the Vaisala technical support by e-mail at helpdesk@vaisala.com . Provide at least the following supporting information: - Name and model of the product in question.
(+32 ... +59 °F and +77 ...+104 °F) ±0.25 °C (±0.45 °F) at -40 ... 0 °C and +40 ... +80 °C (-40 ... +32 °F and +104...+176 °F) ±0.4 °C (±0.72 °F) Temperature sensor Pt1000 RTD 1/3 Class B IEC 751 VAISALA _________________________________________________________________...
Page 16
QUICK GUIDE ______________________________________________________________ Analog Inputs Property Description / Value 2 Channel Current input signals 0-22 mA Resolution: 0.67 µA Accuracy: ±0.15 % F.S. at +25 °C Input Impedance: 62 Ohms 2 Channel Voltage input signals 0-5 V, 0-10 V Resolution 0.0034% F.S. ±0.15 % F.S.
Page 17
8169A-G2M5477 (RSS-210), CE: EU ID # 0681 (ETSI EN 301 489-1, 489-17, 328, EN 55022 Class B, EN61000 4-2, 4-3, 4-6, 4-8, EN 60950) Wi-Fi Certified: WFA7649 United States requirements for unintentional radiators, FCC 47 CFR Part 15-2011 Subpart B. VAISALA _________________________________________________________________...
Page 18
QUICK GUIDE ______________________________________________________________ Property Description / Value Canadian requirements for unintentional radiators, IC ICES- 003:2004 European Union CE Marking requirements for process control, measurement, and laboratory equipment (EMC Directive 2004/108/EC):EN 61326-1:2006 for emissions and immunity EN 61326-2-3:2006 for emissions and immunity of transducers with signal conditioning EN 61000-3-2:2006+A1:2009 +A2:2009 for harmonics...