Linbus Connectors - GE Profile PHB925SB1SS Technical Service Manual

30-in. free standing induction range
Table of Contents

Advertisement

LINbus Connectors

Caution: To prevent damage to LINbus (Local
Interconnect Network bus) connections, properly
use (as shown below) a Molex 69008-1070 tool when
removing LINbus connectors.
Note: A Molex 69008-1070 tool will be provided with
any part that requires the LINbus connectors to be
removed.
Molex 69008-1070 Tool
Do not use front-to-back motion to remove LINbus
connector.
INCORRECT
Correct way: Use side-to-side motion to remove the
LINbus connector.
LINbus is a communication network comprised
of a LIN master and one or more LIN slaves. The
main logic board acts as the LIN master while
the RPSM, bridge, fi lter, and generator boards
are the LIN slaves. (See
All of these components receive a signal to
perform a specifi c task, but only the appropriate
component will act on the message and
respond accordingly. The component which acts
on the specifi c task is based on programming.
Since the LINbus signal is a digital control signal,
special equipment, such as an oscilloscope, is
required to measure it.
– 52 –
CORRECT
Note
.)
Operation Overview