To replace the outer door assembly:
1.
Remove the inner door assembly. (See
remove the inner door assembly, this section.)
2.
Remove the two 1/4-in. hex-head screws from
the heat defl ector.
3.
Lower the heat defl ector to fully expose the 2
screws that attach the handle and top trim to
the outer door frame.
4. Remove the two 1/4-in. hex-head screws that
attach the handle and top trim.
Note: When installing the door handle, make sure
the handle is level with the top of the door before
attaching the heat defl ector. An enlarged hole for
the right side screw has been provided for this
adjustment.
5. Remove the three 1/4-in. hex-head screws (3
from each side) that attach the bottom trim to
the outer door frame.
6. Slide the bottom trim and the glass out of the
outer door frame.
To
Note: Two arrows on the glass indicate the correct
orientation of the glass when it is installed. The side
with the arrows is to be placed facing the outside of
the frame with arrows pointing toward the top.