To remove the inner door assembly:
1.
Remove the door. See previous page.
2.
Place the door assembly, gasket side up, on a
protective surface.
3.
Remove the three 1/4-in. hex-head screws from
the bottom of the door assembly.
4.
Remove the 2 Phillips-head screws from the top
of the inner door assembly.
Note: When installing the inner door assembly, fi rst
capture each top screw using the retainer/spacer.
Screw
Note:
The inner door assembly is heavier than the
outer door assembly.
It may be necessary to carefully use a putty
knife in the following step.
5.
Separate the inner door assembly from the
outer door assembly.
To replace the inner door assembly:
Remove the inner door assembly. (See To remove
the inner door assembly.)
1.
2.
Retainer/Spacer
– 29 –
Remove the three T-20 Torx screws (3 on each
side) that attach each door hinge to the inner
door. Carefully turn the door over and remove
both door hinges.
Remove the six 1/4-in. hex-head screws that
attach the inner window glass assembly to the
heat barrier.
(Continued next page)