Your meter at a glance
8
1
7
6
2
5
3
4
Symbols at a glance
1
2
3
17
4
5
18
16
6
15
7
14
8
13
12
9
11
10
Symbols appearing in the numeric
18
fi eld:
Result lower than 10 mg/dL
(0.6 mmol/L)
Result higher than 600 mg/dL
(33.3 mmol/L)
+ fl ashing
: code chip not
correctly inserted into the meter
or missing
+
: average cannot be
calculated
qrg_05241618001_02_En.indd 1
Display
1
S button (retrieving settings for time
2
and date)
Measuring window cover
3
Measuring window (underneath the
4
cover)
Test strip guide
5
M button (retrieving test results from
6
the memory, changing time / date)
Code chip
7
Infrared window
8
Memory or average
1
Battery almost empty
2
Settings: changing time and date
3
With average being displayed: number
4
of days covered
Flashing: too much light
5
Flashing: testing is in progress or
6
average is being calculated
General fl ag
7
Error messages
Test strip not inserted correctly /
completely; test strip removed
and not re-inserted
Code chip from a different
system
Code chip cannot be read; code
chip from a different system
Measuring window dirty, test
strip is bent / not positioned
straight and fl at
14
13
9
12
10
11
Unit of measurement for blood
8
glucose result
Test strips past their expiry date
9
+
Flashing: test strip removed
10
11
before blood was applied
Flashing: prompt to apply blood to
11
the test strip
Code number display, fl ashing:
12
code chip is missing
After Meals fl ag
13
Used test strip inserted,
measuring window dirty, test
strip not inserted correctly /
completely
Blood or control solution applied
too early, test strip bent / moved,
strong electromagnetic fi eld
Code chip removed while testing
was in progress
Blood Glucose Meter
Quick Reference Guide
Code chip slot
9
Code chip (inserted)
10
Type plate
11
Battery compartment
12
Battery (type CR 2032)
13
Locking catch for opening the battery
14
compartment
14
Before Meals fl ag
Temperature outside the permitted
15
range
Flag for performance check
16
Add-on if time is in 12-hour format
17
Test strip bent / moved, test strip
not inserted correctly /
completely
Meter error
Too little blood or control
solution applied
Temperature too low or too high
for testing
18.09.2008 13:10:19

Advertisement

loading

Summary of Contents for Accu-Chek Acc-Chek Ative

  • Page 1 V6/5 – QRG_05241618001_02_EN_200x228mm – PMS 5445 V6/6 – QRG_05241618001_02_EN_200x228mm – PMS 327 Blood Glucose Meter 0088 Quick Reference Guide ACCU-CHEK is a trademark of Roche. Roche Diagnostics GmbH 68298 Mannheim, Germany www.accu-chek.com Your meter at a glance Code chip slot...
  • Page 2 Removing the protective Coding film from the battery This Quick Reference Guide does not replace the detailed Instructions for use for your Accu-Chek Active blood glucose meter. Please refer to the safety instructions contained in the Instructions for use. Testing blood glucose Setting the time and date Turning the meter on: Press...

This manual is also suitable for:

Active