GE JBP63 Owner's Manual page 37

Self-cleaning radiant range
Table of Contents

Advertisement

5
4-Wire Power Cord Installation
WARNING:
is connected to the neutral terminal located in the center of the
connector block. The power leads must be connected to the outside
(brass colored) terminals. The 4th grounding lead must be connected
to the frame of the range with the grounding plate and grounding screw.
Remove the 3 screws from the connector block.
a
Remove the grounding screw and strap from the connector block middle
b
location and the screw connection to the frame of the range.
Insert screws through each power cord terminal ring and into connector
c
block until screw engages nut. Be certain that the center wire is connected
to the center screw of the connector block. Tighten screws securely.
Attach ground wire to the frame of the range.
d
Before
The neutral wire of the supply circuit
Neutral terminal
Ground Strap
(grounding to range)
After
Grounding to range
Neutral terminal
Grounding
plate
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jbp75Jbp76Jbp77Jbp66Jbp78Jbp60

Table of Contents