Dimensions And Clearances; Important Safety Instructions - GE 164D3333P185-1 Owner's Manual

20" and 24" gas ranges
Table of Contents

Advertisement

Installation of the range.
Read these instructions completely and carefully.

Dimensions and Clearances

Provide adequate clearances between the range and adjacent combustible surfaces.
40
1
2
40
1
4
*Depth including handle: 25-9/16.
*Depth to front of control knobs: 26-1/8.

Important Safety Instructions

Installation of this range must conform with local
codes, or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1, latest
edition. In Canada, installation must conform
with the current Natural Gas Installation Code,
CAN/CGA-B149.1 or the current Propane
Installation Code, CAN/CGA-B149.2, and with
local codes where applicable.
This range has been design-certified by the
American Gas Association according to ANSI
Z21.1, latest edition and Canadian Gas
Association according to CAN/CGA-1.1 latest
edition. As with any appliance using gas and
generating heat, there are certain safety
precautions you should follow. You will find
these precautions in the Important Safety
Instructions in the front of this guide. Read them
carefully.
A range should NOT be installed directly over
kitchen carpeting unless an insulating pad of
1/4-inch thick piece of plywood is placed
24
between the range and carpet.
25-1/2 *
A
from wall
to front of
control panel
36
24
B
Minimum to
30
cabinets on
Minimum
18
either side
of range
36
36
0 clearance below cooking top and at rear of range
Models
A
20 Wide
20
20
24 Wide
24
24
Be sure your range is properly installed by a
qualified installer or service technician.
This range must be electrically grounded in
accordance with local codes, or in their
absence, with the National Electrical Code
ANSI/NFPA No. 70, latest edition and
Canadian Gas Association according to
CAN/CGA-1.1 latest edition. See Electrical
Connection Information.
Before installing the range in an area covered
with linoleum or any other synthetic floor
covering, make sure the floor covering can
withstand heat at least 90°F. above room
temperature without shrinking, warping or
discoloring.
Make sure the wall coverings around the range
can withstand the heat generated by the range.
Make sure all controls remain in the OFF
position when the range is not in use.
C
Minimum to wall on
either side of range
Maximum depth
above 36 height
for cabinets above
range top
B
C
3
2
8
3
0
8
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents