Download Print this page
Vaisala HMP231 Configuration
Vaisala HMP231 Configuration

Vaisala HMP231 Configuration

Humidity and temperature transmitter

Advertisement

Quick Links

HMP231 Humidity and Temperature Transmitter
For wall mounting
Industrial humidity and temperature transmitter
Transmitter
RH+T
RH+T+Td
type
RH+T+a+Tw+x
RH+T+Td+a+Tw+x+h
RH+T+h
Display
no display
display on transmitter cover
Probe length
120 mm
Power supply &
24 V, no connectors
connectors
24 V, shared connector for power supply and analog outputs
Using serial interface:
24 V, connector for RS232C
24 V, 2 connectors: RS232C and analog outputs+power supply
24 V, 2 connectors shared for power supply and RS485
Serial interface
RS 232C
RS 485/RS 422
current loop
Sensor protection
sintered stainless steel filter (16452)
PPS plastic grid & stainless steel netting (16720HM)
PPS plastic grid (16562)
Analog output
4...20 mA
signals
0...20 mA
(Ch1 and Ch2)
0...1 V
0...5 V
0...10 V
Parameters for the
RH
(0...100 %RH)
analog outputs
T
(range: see below)
(If available in the
Td
(-40...+60 °C)
chosen transmitter
a
(0...160 g/m3)
type)
Tw
(0...+60 °C)
x
(0...160 g/kg d.a.)
h
(-40...+460 kJ/kg)
(Ch1 and Ch2)
Analog output range -20...+60 °C
for temperature
-40...+60 °C
0...+60 °C
Units (local display
metric
and serial interface) non-metric
Regaining option *)
no regaining
and sensor type
regaining
Manual language
No manual
English
German
French
Finnish
*) Humidity sensor regaining can be used to reduce the effects of some chemical contaminants.
If the regaining option is chosen, the sensor must be protected either with a sintered filter or
with a PPS plastic grid with steel netting; the PPS plastic grid can not be used.
For further information about this option, please see product data sheet or contact Your Vaisala representative.
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.
End customer:
Legacy configuration codes
HMP231
A
B
C
D
F
channel 1
channel 2
(-40...+140 °F)
(0...69.9 gr/ft3)
(+32...+140 °F)
(0...1120 gr/lb)
(-17.2...+197.8 Btu/lb)
channel 1
channel 2
(-4...+140 °F)
(-40...+140 °F)
(+32...+140 °F)
(HUMICAP K)
(HUMICAP KC)
Example of order code with typical settings:
HMP231 A
A
1
2
A
0
4
8
9
9
A
B
C
1
2
3
A
A
B
B
C
C
D
D
E
E
1
A
0
A
1
A
A
Valid from 25th February 2003
A
1
1
2
2
3
3
4
4
5
5
6
6
7
7
A
B
C
1
2
A
3
2
A
B
C
D
E
TOTAL
QTY
TOTAL VALUE
B
1
2
A
1
A
3
PRICE

Advertisement

loading

Summary of Contents for Vaisala HMP231

  • Page 1 PPS plastic grid with steel netting; the PPS plastic grid can not be used. For further information about this option, please see product data sheet or contact Your Vaisala representative. Selections in bold are included in the prices of the basic versions.
  • Page 2 Please note that if mains power (115/230V) is selected regaining cannot be used. For further information about this option, please see product data sheet or contact Your Vaisala representative. Selections in bold are included in the prices of the basic versions.
  • Page 3 *) Humidity sensor regaining can be used to reduce the effects of some chemical contaminants. Please note that if mains power (115/230V) is selected regaining cannot be used. For further information about this option, please see product data sheet or contact Your Vaisala representative. TOTAL VALUE Selections in bold are included in the prices of the basic versions.
  • Page 4 Please note that if mains power (115/230V) is selected regaining cannot be used. For further information about this option, please see product data sheet or contact Your Vaisala representative. Selections in bold are included in the prices of the basic versions.
  • Page 5 Please note that if mains power (115/230V) is selected regaining cannot be used. For further information about this option, please see product data sheet or contact Your Vaisala representative. Selections in bold are included in the prices of the basic versions.
  • Page 6 Please note that if mains power (115/230V) is selected regaining cannot be used. For further information about this option, please see product data sheet or contact Your Vaisala representative. Selections in bold are included in the prices of the basic versions.

This manual is also suitable for:

Hmp233Hmp234Hmp235Hmp237Hmp238