Status Registers (Read-Only)

Table 43
HMW90 Modbus Status Registers
Name
Error code (bits 15...0)

Configuration Registers

Configuration parameter registers are used to configure the measurement.
Writing out-of-range values is silently ignored.
Elevation is linked to pressure according to the following equation:
p = 101325 (1 - 2.25577 10
where p is pressure in Pa and h is altitude above sea level in m. This
means that changing altitude will also change pressure and vice versa.
Table 44
HMW90 Modbus Configuration Parameter Registers
Metric
Metric unit &
integer
valid range
Address
Description
0513,6913
0 = no errors
-5
5.25588
h)
Non-metric
Non-metric
float
integer
7179...7180 7430 (×1)
Non-metric unit
& valid range
700 ... 1100 hPa
-2300 ... 10000 ft