Installation
Instructions
ELECTRICAL CONNECTIONS (CONT.)
[]
3-WIRE
POWER CORD iNSTALLATiON
WARNING:
The neutral or ground
wire of the power cord must be connected
to the neutral terminal
located in the center
of the terminal
block. The power leads must
be connected to the lower left and the lower
right terminals
of the terminal
block.
Remove the 3 lower terminal
screws from
the terminal
block. Insert the 3 terminal screws
through
each power cord terminal ring and
into the lower terminals of the terminal
block.
Be certain that the center wire (white/neutral)
is connected
to the center lower position of
the terminal
block. Tighten screws securely
into the terminal
block.
DO NOT remove the ground
strap
connection.
Ground plate
/
OUl
0
block
____(appearance
may vary)
Neutral
terminal
Ground
strap
Power cord--------_
r_
Skip to step 8 and proceed with
the installation.
4-WIRE
POWER CORD INSTALLATION
,A
D
rsq
WARNING:
The neutral wire of the supply
circuit must be connected to the neutral
terminal located in the lower center of the
terminal block. The power leads must be
connected to the lower left and the lower right
terminals of the terminal block. The 4th
grounding lead must be connected to the frame
of the range with the ground plate and the
ground screw.
Remove the 3 lower terminal screws from the
terminal block. Remove the ground screw and
ground plate and retain them.
Cut and discard the ground strap.
DO NOT DISCARDANY SCREWS.
Insert the one ground screw into the power cord
ground wire terminal ring, through the ground
plate and into the frame of the range.
Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and into
the lower terminals of the terminal block. Be
certain that the center wire (white/neutral) is
connected to the center lower position of the
terminal block. Tighten screws securely into the
terminal block.
Before
/A
und strap
_4/--J
_rc_inalf
_
Neutral
Ground strdp
terminal
After
Neutral
terminal
block
screw
Ground plate
(grounding
to ra_e)
r_
Skip to step 8 and proceed with the installation.