Download Print this page

GE Appliances XL44 JGBP24 Use & Care Manual And Installation Instructions page 43

Self-cleaning gas range
Hide thumbs Also See for Appliances XL44 JGBP24:

Advertisement

[7 €ONVERTTHEovEN BURNER ORIFICES
Oven Burner
1. Remove oven door, storage drawer or broiler
drawer, oven bottom and burner baffle (on some
models). The lower burner
orifice
spud is
located behind the storage drawer, broiler
drawer or kick panel. (On some models, a metal
shield must be removed to access the orifice.)
2. To convert to LP gas,
use a 1/2" wrench to turn
the lower burner orifice
spud clockwise.
Tighten the
spud only until it is snug.
To prevent damage, do
not overtighten
the spud.
To convert to natural
gas,
loosen the spud about 2 turns.
Broil Burner (on some models)
J
.
_
/
To convert
to LP gas, use a 1/2" wrench
to
turn the upper
burner
orifice
spud clockwise.
Tighten spud only until it is snug with the base.
To prevent
damage, do not overtighten
spud.
To convert
to natural
gas, loosen
the spud
about 2 turns.
[7 CONVERT AIR ADJUSTMENTSHUTTER
For LP gas, loosen
the
Phillips head screw and
rotate
the shutter
to the
Screw--,
full open position. With
baffle in place, flames
.
Air Shutter _
should have approximately
1-inch blue cones and
should not extend beyond
the edges of the burner baffle. After 30 seconds
9 f burner operation, check for flames lifting off
burner ports. If lifting is observed, gradually
reduce air shutter
opening
until flames are
stabilized.
For ,natural
gas, the shutter should be open
1/2' or about 3/4 of the way open.
[7
CHECK FOR LUKS
When
all connections
have been made, make
sure
all range controls
are in the off position
and turn
on the main gas supply valve. Use a liquid leak
detector
at all joints
and connections
to check for
leaks in the system.
CAUTION: DO NOT USE A FLAME TO
CHECK FOR GAS LEAKS.
When using test pressures greater than 1/2 psig
to pressure test the gas supply system of the
residence, disconnect the range and individual
shut-off valve from the gas supply piping. When
using test pressures of 1/2 psig or less to test the
gas supply system, simply isolate the range from
the gas supply system by closing the individual
shut-off valve.
I
(continued
next page)
43