Adjustment Section - Pages 28 - 30 Travel Limit Adjustments - Craftsman 139.53800SRT Owner's Manual

1/2 hp
Hide thumbs Also See for 139.53800SRT:
Table of Contents

Advertisement

Adjustment
Section:
Pages 28 - 30
Adjustment Step 1
Adjust
the UP and DOWN
Limits
Do not make any limit adjustments
until the
safety reversing sensors are completely
installed.
,
IH .....
==,1=
......................
Limit adjustment settings regulate the points at
which the door will stop when moving up or down.
The door will stop in the up direction if anything
interferes with door travel. The door will reverse in
the down direction if anything interferes with the
door travel (including binding or unbalanced doors).
To operate the opener, press the Door Control push
button. Run the opener through a complete travel
cycle.
• Does the door open and close completely?
• Does the door stay closed and not reverse
unintentionally when fully closed?
tf your door passes both of these tests, no limit
adjustments are necessary unless the reversing test
fails (See page 30).
Adjustment procedures are outlined below. Run
the opener through
a complete travel cycle after
each adjustment.
Repeated operation of the opener during
adjustment procedures may cause the motor to
overheat and shut off. Simply wait 15 minutes
and try again.
Read the procedures carefully before proceeding to
Adjustment Step 2. Use a screwdriver to make limit
adjustments.
Improper
adjustment
of the travel limits
will
interfere
with the proper
operation
of the
safety
reverse
system.
The door might not
reverse
properly
when
required
and could
seriously injure or kill someone under it. Test
the
safety
reverse
system
following
all
adjustments to the travel limits. See page 30.
Left Side Panel
Limit A_ustment
S_ews
'IL " ®)I
It-- TRAVm.
Adjustment L.t_o!
How and When to Adjust the Limits
If the door does not open completely
but opens at least five feet
Increase up travel Turn the UP limit adjustment
screw clockwise. One turn equals 2" of travel.
If door does not open at least 5 feet: Adjust the
UP (open) force as explained in Adjustment Step 2.
If the door does not close completely
Increase down travel. Turn the DOWN limit
adjustment screw counterclockwise. One turn
equals 2" of travel.
If door still won't close completely, try lengthening
the door arm. (See Page 26°)
If you have adjusted the door arm to the maximum
length and the door still wilt not close completely,
lower the header bracket. See Installation Step t,
pages 12 and 13.
If the opener reverses in fully closed position
Decrease down travel. Turn the DOWN limit
adjustment screw clockwise. One turn equals 2" of
travel
If the door reverses when closing and
there is no visible interference to travel cycle
If the opener lights are flashing, the Safety Reversing
Sensor is obstructed° Remove the obstruction.
Test the door for binding: Pull the emergency release
handle_ Manually open and close the door. If the door
is binding, call for garage door service, tf the door is
not binding or unbalanced, adjust the DOWN (close)
force. See Adjustment Step 2o
28

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents