Tools You Will Need; Location Guidelines - GE XL44 J2B915 Owner's Manual And Installation Instructions

Xl44 self-cleaning dual fuel convection
Table of Contents

Advertisement

TOOLS YOUWILL NEED
Phillipsand flat-blade screwdrivers
Penciland ruler
Twopipe wrenches(one for backup)
Open-endor adjustable wrench
Nut driver or wrench. 1/4"
DnTl
ADDITIONAL MATERIALS YOUMAY NEED:
Gaslineshut-off valve
Pipejolbt sealant or UL-approved pipe thread tape with
Teflon*that resists action of natural and LPgases.
*Teflon.Registeredtrademark of DuPont
Flexiblemetal apphanceconnector (1/2" LD.).A 5-foot
length is recommendedfor ease of installation but other
lengths are acceptable. Neveruse an o/d connector when
lbstalhbg a new range.
Flare unionadapterforconnection togassupply line
(3/4" or 1/2" NPTx1/2" LD.)
Flareunionadapterforconnection topressure regulator
on range (1/2" NPTx 1/2" LD.)
Liquid leakdetectoror soapy water
Lagboltor 1/2" O.D.Sleeve anchor ( forconcrete
floorsonly).
Squeeze C onnector matchingthesloeof thebracket
opening (ontherange backbehindthe wkingcover) a nd the
houseconduit Obtainonlyif replacing thepowercordwith
conduit
LOCATION GUIDELINES
Do not locate the range where it may be subject to strong drafts. Any openings in the floor or waft
behind the range should be sealed. Make sure the openings around the base of the range that
supply fresh air for combustion and ventilation are not obstructed by carpeting or woodwork.
Your range, like many other
household
items,
is heavv and can settle into soft floor coverings
such as cushioned
vinyl or caq)eting.
Use care
when
moving
tile range
on this t,ipe of flooring.
It is recommended
that tile following
simple
and
inexpensive
instructions
be followed
to protect
VO/II"
_100I;
Tile range should
be installed
on a sheet _ff
plywood
(or similar
material).
When
tile floor
covering
ends at tile fl'ont of tile range, tile area
that tile range will rest on should
be built up
with plywood
to tile same level or higher
than
tile floor covering.
This Mll allow tile range to be moved t_r cleaning
or servicing.
_Mso, make sm'e yam" floor covering
will withstand
180°E (See the Installation Safety
Instructions section.)
Make sure tile wall coverings
arotmd
your range
can withstand
the heat generated
(up to 200°F)
bv tile range.
(See tile Installation Safety Instructions
section.)
IMPORTANT!
Remove aft tape and packaging.
Make
sure the burners
are properly
seated and level.
Take the accessory
pack out of the oven.
Check to be sure that no range parts have come loose during
shipping.
41

Advertisement