GE JGBP35 Owner's Manual & Installation Instructions page 37

Self-cleaning gas ranges
Table of Contents

Advertisement

Installation
Instructions
[]
PROVIDE ADEQUATE
GAS SUPPLY
Your
rmlge
is designed
to operate
at a pressure
of 4" of
water
cohunn
on natural
gas or, if desi_md
for LP gas
(propmm
or butane),
10" of water
cohunn.
Make
sure
you are
SUl)plyii_g
your
range
with
the
_'pe
of
gas fin" which
it is designed.
This
range
is convertible
fi_i" use on natural
or l)ropane
gas. If you
decide
to use this range
on LP gas, convei_ion
must
be made
b)' a qualified
12 installer
before
attempting
to operate
the
range
on that
gas.
For proper
operation,
the
pressm'e
of natm'al
gas
supplied
to the
regulator
illtlSt
be between
4" and
13"
of water
cohlil/n.
For I,P gas, the pressure
supplied
must be between
10"
and l 3" ot water cohmm.
When
checking
fin" proper
operation
of the regulatm,
the inlet pressure
must be at least 1" greater
than the
operating
(manilold)
pressm'e
as given above.
The pressm'e
regulator
located
at the inlet of the range
manilold
illtlSt remain
in the SUl)ply line regardless
ot
whether
natural
or I,P gas is being
used.
A flexible
metal appliance
com_ector
used to com_ect the
range to the gas supply line should
have an I.D. otl/2"
and be 5 fl_et in length
fin" ease ot installation.
In Canada,
flexible
com_ecto_
must be single wall metal cmmecto_
no longer
than 6 teet in length.
[]
CONNECT THE RANGE TO GAS
Shut
off the
main
gas supply
valve
before
discommcth_g
the old rmlge
and
leave
it off until
the new hookup
has
been
completed.
Don't
forget
to relight
the pilot
on other
gas applimlces
when
you turn
the gas back
on.
Because
hard
piping
restricts
movement
of the
range,
the
use of a CSA
International-certified
flexible
metal
appliance
cmmector
is recommended
mdess
local
codes
require
a hard-i)iped
connection.
Never
use an old connector
when
installing
a new range.
If the
hard
piping
method
is used,
you must
careflflly
align
the
I)ipe;
the
range
cmmot
be moved
alter
the
connection
is II/ade.
To prevent
gas leaks, put pipe joint
compotmd
on, or
wrap pipe thread
tape with Teflon*
arotmd,
all male
(external)
pipe threads.
A. Install a manual
gas line shut-off'wflve
in the gas line in
an easily accessed
location
outside
of the range.
Make
sm'e everyone
operating
the range knows where and
how to shut off the gas supply
to the range.
B. Install male 1/2" flare union
adapter
to the 1/2" NPT
internal
thread
at inlet of regulator:
Use a backup
wrench
on the regulator
fitting
to avoid damage.
When
installing
the range fl'om the fl'ont, remove
the
90 ° elbow tot easier installation.
C. Install male
1/2" or 3/4" flare ration adapter
to the
NPT internal
thread
of the manual
shut-off \_flve,
taking care to back-up
the shut-off \_flve to kee I) it
fl'om mrning.
D. Com_ect
flexible
metal appliance
connector
to the
adapter
on the range.
Position
range to pemfit
com_ection
at the shut_fl
\zflve.
E. X_]_en all connections
have been made,
make sure
all range
controls
are in the off position
and mrn on
the main gas sui)ply \:five. Use a liquid leak detector
at all joints
and connections
to check fin" leaks in
the system,
When
using
test
i)ressures
greater
than
l/2
psig
to
i)ressure
test
the
gas
supi)ly
s):stem
of the
residence,
disconnect
the
range
and
individual
shut-off
wflve
WARNING:
DO NOT
USE A FLAME
TO
CHECK
FOR
GAS LEAKS.
fl'om the gas supply
piping.
When
using test pressm'es
of 1/2
psig or less to test the gas SUl)ply system,
simply
isolate
the range
fl'om
the gas supply
system
by closing
the individual
shut-off'
wflve.
*Teflon: Regist_ red trademark
of DuPont
37