Installationof the range.
Read theseinsf_ctions completely and carefully.
[]
Provide Adequate Gas Supply
Yourrangeis designedto operateat a pressureof 4" of water columnon nature/gas or,if designedfor
LPgas (propaneor butane), 10"of water column.
Make sure you are supplying your range with the
type of gas for which it is designed.
This range is convertible for use on natumlor
propane gas. If you decide to use this range on LP
gas, conversion must be made by a qualified LP
installer before attempting to operate the range on
that gas.
For proper
operation, the pressure of natural gas
supplied
to the regulator
must be between 4" and
13" ofwatec column.
For LP gas, the pressure supplied
must be between
10" and 13" of water column.
When checking for proper operation of the
regulator, the inlet pressure must be at least 1"
greater than the operating (manifold) pressure as
given above.
The pressure regulator
located at the inlet of the
range manifold
must remain in the supply line
regardless of whether natural or LP gas is being used.
A flexible metal appliance
connector
used to
connect the range to the gas supply line should have
an I.D. of 1/2" and be 5 feet in length for ease of
installation. In Canada, flexible connectors
must
be single wall metal connectors
no longer than
6 feet in length.
[]
Connect the Range to Gas
Shutoff themain gas supplyvalvebefore disconnecting the oldrange and leaveit off untilthe new
hook-uphas been completed.Don'tforget to relightthe pilot on othergas applianceswhen youturn
the gas back on.
Because hard piping restricts movement
of the
range, the use of an A.G.A.-cerdfled
flexible metal
appliance
connector
is recommended
unless local
codes require a hard-piped
connection.
[]
Never use an old connector
when installing a new
[]
range. If the hard piping method
is used, you must
carefully align the pipe; the range cannot be moved
after the connection
is made.
[]
To prevent gas leaks, put pipe joint compound
on,
or wrap pipe thread tape with Teflon* around, all
male (external)
pipe threads.
[]
Install a manual gas line shut-offvalve in the gas
line in an easily accessed location outside of the
range. Make sure everyone operating the range
knows where and how to shut off the gas supply
to the range.
Install male 1/9" flare union adapter
to the
1/2" NPT internal
thread elbow at inlet of
regulator.
On models equipped
with standard
twin burners,
install the male pipe thread end
of the 1/2'
flare union adapter
to the 1/_'
NPT internal
thread at inlet of pressure
regulator.
Use a backup wrench
on the
regulator
fitting to avoid damage.
When installing the range from the front,
remove the 90 ° elbow for easier installation.
[]
Install male 1/2" or 3/4" flare union adapter
to
the NPT internal
thread of the manual shut-off
valve, taking care to back-up the sbut-offvalve
to keep it from turning.
Connect flexible metal appliance
connector to
the adapter
on the range. Position range to
permit connection
at the shut-offvalve.
When all connections
have been made,
make sure all range controls are in the off
position and turn on the main gas supply valve.
Use a liquid leak detector
at all joints and
connections
to check for leaks in the system.
CAUTION:
go Nor USE A FLAME TO
CHECX
FOR S AS L EAXS.
When using test pressures greater than 1/2 prig to
pressure test the gas supply system of the residence,
disconnect the range and individual shut-offvalve
from the gas supply piping. When using test
pressures of 1/2 psig or less to test the gas supply
system, simply isolate the range from the gas supply
system by closing the individual shut-offvalve.