3.
HP Command View EVA responds with the page.
4.
The web server sends it to the browser.
These errors indicate that a problem is occurring with this normal interaction.
possible causes of these errors and their corrective actions.
Resolution
Table 7 Possible causes and corrective actions for HTTP 404 and HTTP 503 errors
404 Error: HP Command View EVA may be initializing
when a browser makes a request. The web returns a 404
(Page Not Found) error because it cannot get the page.
404 Error: A .frm (HTML) file may be missing in the HP
Command View EVA directory structure. This can occur
if the files were changed or if the HP Command View
EVA installation went amiss.
503 Error: HP Command View EVA may be down when
a browser makes a request. The web server returns a 503
(No Service) error because it cannot access the page.
Browser timeout: The appliance may be down or the web
server may be unavailable when a browser makes a re-
quest to HP Command View EVA. In this case, the browser
will time out internally.

Unknown storage system

Symptom
HP Command View EVA reports an unknown storage system for a storage system that should be
displayed.
Cause of the error
HP Command View EVA may have lost communication with the controllers. Two possible scenarios
are:
The HBA in the management server may have timed out commands to the controllers. See
storage system—cause
The controllers are running a version of XCS that HP Command View EVA does not recognize.
See
"Unknown storage system—cause
Unknown storage system—cause 1
When the fabric is heavily loaded, the FC adapter in the management server may time out commands
to the controllers. If this occurs, the storage system appears in the Unknown state.
Corrective Action for Unknown Storage System Cause 1
This scenario should correct itself in less than one minute. Alternately, you can perform a Rediscover
operation to initiate new commands to the controller.
HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array Updating Product Software Guide (XCS
Possible Cause
1" on page 69 below.
2" on page 70.
Table 7
Corrective Action
Retry the request by clicking the Refresh/Re-
load button on the browser.
Reinstall HP Command View EVA.
Retry the request when HP Command View
EVA is up.
Retry the request when the appliance and HP
Command View EVA are up.