User Action: If the spare drive status is failed, replace the drive.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqDaCntlrHwLocation
•
cpqDaSpareCntlrIndex
•
cpqDaSparePhyDrvIndex
•
cpqDaSpareStatus
•
cpqDaSpareBusNumber
•
cpqDaSpareBay
Supporting SNMP Trap Description: "Spare Status is now [cpqDaSpareStatus]."
NT Event ID: 1202 (Hex)0x843504b2 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Physical Drive Status Change.
Log Message: The physical drive in %4, port %5, bay %6 with serial number "%7", has a new status
of %2.
SNMP Trap: cpqDa6PhyDrvStatusChange - 3036 in CPQIDA.MIB
Symptom: Physical Drive Status Change. This trap indicates that the agent has detected a change in
the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current
physical drive status.
User Action: If the physical drive status is failed(3) or predictive Failure(4), replace the drive.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqDaCntlrHwLocation
•
cpqDaPhyDrvCntlrIndex
•
cpqDaPhyDrvIndex
•
cpqDaPhyDrvBusNumber
•
cpqDaPhyDrvBay
•
cpqDaPhyDrvModel
•
cpqDaPhyDrvFWRev
•
cpqDaPhyDrvSerialNum
•
cpqDaPhyDrvFailureCode
•
cpqDaPhyDrvStatus
Supporting SNMP Trap Description: "Physical Drive Status is now [cpqDaPhyDrvStatus]."
NT Event ID: 1203 (Hex)0x843504b3 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Physical Drive Threshold Exceeded.
Log Message: The physical drive in %4, port %5, bay %6 with serial number "%7", has exceeded a
drive threshold.
Storage agents 65