HP 108164-003 - ProLiant - 800 Reference Manual page 18

Microsoft windows event id and snmp traps reference guide for use with smartstart version 8.25
Table of Contents

Advertisement

Log Severity: Warning (2)
Log Message: Unable to allocate memory. This indicates a low memory condition. Rebooting the
system will correct this error.
Event identifier: cpqhsmsg.dll - 2049 (Hex)0x84350801 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to read from the registry. This error can be caused by a corrupt registry or a
low memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 2050 (Hex)0x84350802 (Service Event)
Log Severity: Warning (2)
Log Message: Could not create the registry sub-key: "%1". This error can be caused by a corrupt
registry or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 2051 (Hex)0x84350803 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to read from the registry. This error can be caused by a corrupt registry or a
low memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 2052 (Hex)0x84350804 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to read "%1" from the registry. This error can be caused by a corrupt registry
or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 2053 (Hex)0x84350805 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to read "%1" from the registry. This error can be caused by a corrupt registry
or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 2056 (Hex)0x84350808 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to create thread. This error can be caused by a low memory condition.
Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 2098 (Hex)0x84350832 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to acquire file system information. This error can be caused by an unformatted
partition or by a partition that has been recently modified. Formatting the partition or rebooting the
server may correct this error.
Event identifier: cpqhsmsg.dll - 2099 (Hex)0x84350833 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to acquire file system information for %1. This error can be caused by a low
memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 2100 (Hex)0x84350834 (Service Event)
Log Severity: Warning (2)
Foundation agents 18