Page 1
INSTRUCTION MANUAL - for the - DT7306 TENS 7000 RECHARGEABLE 4 CHANNEL...
Page 2
TENS 7000 RECHARGEABLE 4 CHANNEL This instruction manual is published by Compass Health Brands Corp. Compass Health Brands Corp. reserves the right to improve and amend it at any time without prior notice. Amendments may however be published in new editions of this manual.
1. INTRODUCTION Indication for Use: TENS: The device is designed to be used for temporary relief of pain associated with sore and aching muscles in the shoulder, waist, back, neck, upper extremi- ties(arm) and lower extremities (leg) due to strain from exercise or normal house- hold work activities.
Page 5
DO NOT USE ON THESE INDIVIDUALS • Pregnant women. • Children or infants. • Persons incapable of expressing their thoughts or intentions. WARNING (CONTINUED) DO NOT USE THIS DEVICE DURING THESE ACTIVITIES • When in the bath or shower. • While sleeping. •...
Page 6
• DO NOT apply ointment or any solvent to the electrodes or to your skin because it will disrupt the electrodes from functioning properly. • The electrodes are already pre-gelled and will adhere to your skin. • To avoid damage to the adhesive surface of the electrodes, put the electrodes •...
Page 7
GENERAL PRECAUTIONS • The patient is an intended operator of the device. • The patient can fully operate the device,but maintenance and modiÿcation of the device can only be done by a service technician authorised by the manufacturer. • The long-term effects of electrical stimulation are unknown. •...
3.1 Front and Rear Panel CH sign Set Control Lead Connector Decrease Button Liquid Crystal Display Increase Button Panel Cover CH Selecting Button Power Control TYPE-C Connector Mode Control Belt Clip 3.2 LCD Display CH4 sign Parameter number display CH3 sign Hz/˜s/s unit sign CH2 sign Compliance meter sign...
4. SPECIFICATIONS 4.1 Technical Information Channel Four, isolated between channels Li-ion Battery 3.7V 500mAh Charging 500mA at least Operating Conditions 5°C – 40°C (41°F – 104°F) with a relative humidity of 30% – 75%,atmospheric pressure from 700 – 1,060 hPa Storage and -10°C –...
Burst Mode Burst Rate: Adjustable, 0.5 – 5Hz Pulse Width: Adjustable, 50 – 300˜s Frequency: Fixed = 100 Hz Normal The Pulse Rate and Pulse Width are adjustable. It generates continuous Mode (N) stimulation based on the setting value. Modulation The Pulse Rate and the Pulse Width modulate automatically in a varied Mode (M) cycle pattern.
MODULATION SD1 (STRENGTH DURATION) SD2 (STRENGTH-DURATION) 4.5 Waveform Information — EMS SYNCHRONOUS (S) ALTERNATE (A) 5. INSTRUCTIONS FOR USE 5.1 Battery Battery charging Insert the TYPE-C plug of the TYPE-C cable into the TYPE-C charging port of the device, and then connect to the Standard USB plug of the TYPE-C cable to the appropriate power supply device which can output 5V d.c., 500mA at least.
NOTES: • When the battery indicator is going to be empty on the LCD, please charge the battery. If the battery power is too low, the device will turn off automatically. • Only use the TYPE-C cable which is provided by the manufacturer. Device must be charged prior to ÿrst use.
C. Connect Lead Wires 1) Before proceeding to this step, be sure the device is completely turned OFF. 2) Insert the lead wires into the output sockets located on the top of the device. (fg. 1) 3) Holding the insulated portion of the connec- tor, push the plug end of the wire into one of the sockets (see ÿg.1);one or two or three or four of wires may be used.
Page 15
C. Set Ramp Up/Down Time for EMS Press once and the number for “Ramp” on the LCD screen will ˜ash.To change the number, press until the desired ramp time is reached. If the default Ramp time is the desired time and no change is needed,press to move on to the next parameter.
G. Connect & Place Electrodes Once the parameters are set, connect electrodes before starting treatment. Take the electrodes out of the sealed package. Connect both pins of each lead wire to the pigtail of an electrode (one electrode will not work). Make sure the metal pin connector is not visible.
B. Check & Delete Accumulative Record When in the individual records menu, press MODE to switch to accumulative records menu. To MODE button simultaneously for 3 seconds and ALL records will be deleted followed by a beeping sound. 5.5 Battery Charging Over time, in order to ensure the functional safety and performance of the device,charging the battery is...
6. If replacement electrodes are necessary, use only electrodes that are the same size (2" x 2") as the electrodes provided with the TENS 7000. 6.2 Storing Device, Electrodes and Lead Wires •...
Reposition the electrodes. If at any time you feel pain Using the electrodes on the or discomfort, stop use same site every time. immediately. Ensure the electrodes are Electrodes are not adhered securely adhered to the The skin becomes to the skin properly skin.
10. ELECTROMAGNETIC COMPATIBILITY (EMC) TABLES • This device should not be used adjacent to or stacked with other equipment. If adjacent or stacked use is necessary, this device should be observed to verify normal operation in the conÿguration in which it will be used. •...
Page 21
TABLE 2 declaration - electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of device should assure that it is used in such an environment. Immunity test IEC 60601 test Compliance level Electromagnetic environment - level...
Page 22
Conducted RF Portable and mobile RF communications equipment IEC 61000-4-6 0.15 MHz to 0.15 MHz to should be used no closer to any part of device, than 80MHz 80 MHz the recommended separation distance calculated 6 V in ISM 6 V in ISM from the equation applicable to the frequency of the and amateur and amateur...
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by 11. LIMITED WARRANTY All TENS 7000 models carry a limited warranty of one year from the date of delivery. The limited warranty applies to the stimulator only and covers both parts and labor relating thereto.
12. FCC COMPLIANCE STATEMENT FCC Supplier's Declaration of Conformity Product Name: TENS 7000 4 CHANNEL Model Number: DT7306 Responsible Party Company Name: Compass Health Brands Corp. Address:6753 Engle Rd Middleburg Heights, OH 44130 Phone Number: 800.871.7858 This device complies with part 15 of the FCC Rules. Operation is subject to the...