Immergas VICTRIX HYBRID Instructions And Recommendations page 72

Hide thumbs Also See for VICTRIX HYBRID:
Table of Contents

Advertisement

Error
Anomaly signalled
Code
Anomaly pump
60
blocked
Air in circulator
61
Return/flow probe
70
exchange
Return and/or flow
75
probe malfunction
Flow and/or return
probes temperature
76
drift
(1) If the block or anomaly persists, contact an authorised company (e.g. Immergas Authorised After-Sales Centre)
(2) The anomaly can only be verified in the list of errors in the "Information" menu
72
Cause
The pump is stopped due to one of the following causes:
Impeller blocked, electrical fault.
Air is detected inside the pump; the pump cannot work.
In case of an incorrect system wiring connection the error
is detected
Possible failure of one or both system return and flow
probes
A malfunction of one or both system return and flow
probes is detected.
UI Status / Solution
Try to unblock the pump as described
in the relative section. If normal
conditions are restored, the system
restarts without having to be reset (1)
Vent the pump and the central heating
circuit. If normal conditions are
restored, the system restarts without
having to be reset (1)
The system does not start (1)
The system does not start (1)
The system does not start (1)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Victrix hybrid 323.030698

Table of Contents