2.8 SETTINGS MENU

Press the "Menu" button to access a list of variables that enable you to customise use of the system.
Set Point Zone
Set Point DHW
Time and Program
Information
Fault history
Esc
The list refers to the panel with firmware revision 2.01.
Hereunder is a list of available menus.
Menu item
Set Point Zone
Set Point DHW
Time and Program
Information
Historical alarm code
Service
Language
Menu item
Set comfort heat
Room temperature in central heating zone Comfort mode
Set economy heat
Room temperature in central heating zone Economy mode
Flow set with room th.
Flow temperature in heating mode with room thermostat
Flow set heat max
Maximum flow temperature with room probe active
Offset temperature for central heating zone (only used with
Offset flow heat
operation with external probe)
Menu item
Set comfort
DHW temperature in Comfort phase
Set economy
DHW storage temperature in Economy phase
Disinfection
Not used on this model
Menu
[ ... ]
[ ... ]
[ ... ]
[ ... ]
[ ... ]
Back
Defines the operating parameters to manage the zone
Defines the operation parameters in domestic circuit mode
Defines the date/time and time operating slots
Display system operating data
Displays the list of the last 10 anomalies
Password protected menu dedicated to a qualified technician
Defines the Control panel operation language
"Set Point Zone" menu.
Description
"Set Point DHW" menu
Description
To browse the menus, which can be accessed by pressing the rela-
tive "RH" or "LH" context buttons, scroll through the sub-menus
displayed by turning the main switch.
Press the said selector to select the one highlighted.
By pressing repeatedly, you can scroll down the menu levels and
go back to a previous level by pressing the "Back" context button.
To exit the menu completely, press the "Esc" button, which will
take you back to the initial page of normal operation.
47
To confirm the parameter change, press the main switch.
MAIN MENU
Description
- 15 ÷ + 15°C
Range
Default
15 ÷ 35 °C
20
5 ÷ 25 °C
17
20 ÷ 80 °C
40
20 ÷ 80 °C
50
0
Range
Default
30 ÷ 60 °C
50
30 ÷ 45 °C
30
-
-
Customised
value
Customised
value