1.24 SEPARATOR KIT INSTALLATION

Type C configuration, sealed chamber and fan assisted separator kit Ø 80/80
This kit allows air to come in from outside the building and the exhaust to exit from the chimney, flue or intubated duct through divided
flue exhaust and air intake pipes.
Combustion products are expelled from pipe (S) (in plastic, so as to resist acid condensate).
Air is taken in through duct (A) for combustion (this is also in plastic).
The intake pipe (A) can be installed either on the right or left hand side of the central exhaust pipe (S).
Both ducts can be routed in any direction.
Assembly of separator kit Ø 80/80 (Fig. 28):
1. Install the flange (4) on the central hole of the appliance, positioning gasket (1) with the circular projections downwards in contact
with the appliance flange.
2. Tighten with the hexagonal head and flat point screws provided in the kit.
3. Replace the flat flange present in the lateral hole with respect to the central one (according to needs) with the flange (3), positioning the
gasket (2) in between.
4. Tighten with the supplied self-tapping screws with drill bit.
5. Fit the bends with male side (smooth) (5) in the female side of the flanges (3 and 4).
6. Fit the intake terminal (6) with the male side (smooth) in the female side of the bend (5) up to the end stop, ensuring that the internal
and external wall sealing plates are fitted
7. Fit the exhaust pipe (9) with the male end (smooth) to the female end of the bend (5) up to the end stop; making sure that the internal
wall sealing plate has been fitted, this will ensure sealing and joining of the elements making up the kit.
7
The kit includes (Fig. 28):
N°1 Exhaust gasket (1)
N°1 Flange gasket (2)
N°1 Female intake flange (3)
N°1 Female exhaust flange (4)
N°2 Ø 80 90° bend (5)
N°1 Intake terminal Ø 80 (6)
5
S
9
4
1
5
6
A
3
2
N°2 Internal wall sealing plates (7)
N°1 External wall sealing plate (8)
N°1 Exhaust pipe Ø 80 (9)
* to complete C
configuration, also provide for a "green range" roof
53
discharge terminal. The configuration on walls opposite the build-
ing is not allowed.
7
8
C
* - C
53
83
28
41