Vertical kit assembly with aluminium tile Ø 80/125 (Fig.26)
To install the kit Ø 80/125 one must use the flanged adapter kit in order to install the flue system Ø 80/125.
1. Install the concentric flange (2) on the flue exhaust of the appliance, positioning gasket (1) with the circular projections downwards in
contact with the appliance flange.
2. Tighten the concentric flange with the screws in the kit.
Imitation aluminium tile installation:
3. Tighten the concentric flange with the screws in the kit.
4. Replace the tiles with the aluminium sheet (4), shaping it to ensure that rainwater runs off.
5. Position the fixed half-shell (5) on the aluminium tile;
6. Insert the intake-exhaust terminal (7);
7. Fit the Ø 80/125 concentric terminal pipe with the male side (smooth) to the female side of the adapter (1) (with lip seals) up to the end
stop, making sure that the wall sealing plate (3) has been fitted; this will ensure sealing and joining of the elements making up the kit.
7
6
5
4
3
2
1
Extensions for vertical kit Ø 80/125 (Fig. 27)
The kit with this configuration can be extended to a max. straight
vertical length of 32 m, including the terminal. If additional com-
ponents are assembled, the length equivalent to the maximum al-
lowed must be subtracted. In this case the special extensions must
be requested.
40
The adaptor kit includes (Fig. 26):
C
33
N°1 Gasket (1)
N°1 Adapter Ø 80/125 (2)
The Ø 80/125 kit includes (Fig.26):
N°1 Wall sealing plate (3)
N°1 Aluminium tile (4)
N°1 Fixed half-shell (5)
N°1 Mobile half-shell (6)
N°1 Concentric intake/exhaust pipe Ø 80/125 (7)
The remaining kit components must not be used