Immergas VICTRIX HYBRID Instructions And Recommendations page 100

Hide thumbs Also See for VICTRIX HYBRID:
Table of Contents

Advertisement

Victrix 24HY
Id
Parameter
Parameter
DHW mini-
S0
mum no. of fan
revs
DHW maxi-
S1
mum no. of fan
revs
Ignition phase
S2
no. of fan revs
Victrix 32HY
Id
Parameter
Parameter
DHW mini-
S0
mum no. of fan
revs
DHW maxi-
S1
mum no. of fan
revs
Ignition phase
S2
no. of fan revs
100
Description
Defines the operating speed of the fan at minimum DHW
output
Defines the operating speed of the fan at maximum DHW
output
Defines the operating speed of the fan during the ignition
phase
Description
Defines the operating speed of the fan at minimum DHW
output
Defines the operating speed of the fan at maximum DHW
output
Defines the operating speed of the fan during the ignition
phase
Range
Default
27 (G20)
20 - 60
(x 50 = RPM)
26 (G31)
121 (G20)
S0 - 140
(x 50 = RPM)
100 (G31)
44 (G20)
40 - 80
(x 50 = RPM)
44 (G31)
Range
Default
27 (G20)
20 - 60
(x 50 = RPM)
27 (G31)
128 (G20)
S0 - 140
(x 50 = RPM)
119 (G31)
56 (G20)
40 - 80
(x 50 = RPM)
56 (G31)
Customised
value
Customised
value