0504 [Execute Cleaning Initial Setting for PCU]
When the photoconductor cleaning unit is replaced, [Execute Cleaning Initial Setting for PCU] is
automatically executed when the counter is reset, so there is no need to execute it manually.
If you have cleaned the photoconductor cleaning unit, execute [Execute Cleaning Initial Setting for PCU]
after attaching the photoconductor cleaning unit. Do not open the front left cover or front right cover
while executing [Execute Cleaning Initial Setting for PCU]. The control panel shows information during
the operation.
Setting Items
[KCMY]
[CMY]
[Black]
[Cyan]
[Magenta]
[Yellow]
*1
[Special]
*1 To use special colors, 5th Station Upgrade Kit is required.
0505 [Photoconductor More Lubricant Mode]
Increase the amount of lubricant to the drum. If ON is selected, the replacement cycle of the
photoconductor cleaning unit may be shortened due to the increase of lubricant amount.
Setting Items
[Black]
[Cyan]
[Magenta]
[Yellow]
*1
[Special]
*1 To use special colors, 5th Station Upgrade Kit is required.
Remarks
Press [Execute].
Values
[Off]
[On]
[Machine: Maintenance]
Default Value
[Off]
19