3. Details of Detailed Settings
This chapter explains the functions of the Detailed settings and the related image quality problems that
can be prevented/improved by adjusting these settings. For detailed procedure, see the
Troubleshooting manual.
Overview
Print Mode
Image quality is adjusted in balance with productivity according to the print mode (BW/FC/FCS/S),
which differ in the maximum toner amount, i.e. bias needed for transfer and heat needed for fusing.
It is important not to mix up the adjustments, especially the items that have similar names like 1232:
[Fusing Temperature].
The following table describes the relation between the pint mode and the image data sent from the color
controller.
Print data
K only
*1
CMYK
*2
CMYK+S
S only
*1 Job is run in FC mode, if the print data contains C, M, or Y.
*2 Job is run in FCS mode, if print data contains C, M, or Y and S.
*3 If the color controller N-50A is connected and white, clear, invisible red, gold and silver toners are installed
in the special color station, check box [High image quality] appears in the [Special Color] tab in Job
Properties of Command WorkStation. If the check is removed, priority is given to Productivity over Image
Quality, as the maximum toner amount will be limited to 260% (identical to FC mode). The [Special Color]
tab does not appear for neon yellow or neon pink.
Print mode
BW
FC
*3
FCS
S
Max toner amount
100%
260%
360%
100%