Immergas VICTRIX HYBRID PLUS Manual page 91

Hide thumbs Also See for VICTRIX HYBRID PLUS:
Table of Contents

Advertisement

Menu item
Enables IU operation in DHW mode if the EU is not sufficient to
Enable DHW integr.
reach the set point.
Enables IU operation in CH mode if the EU is not sufficient to
Enable heat. integr.
reach the set point.
Wait time to reach the set point before the activation of
DHW waiting time
integration in domestic hot water production (when combined
with a storage tank unit).
Waiting time to reach the setting set before activation of the
Heat. waiting time
integration in room heating.
If the flow temperature of the outdoor unit is lower than the
heating-set value minus the activation band divided by 2, then
Integration band
after a period equal to the activation delay time, the indoor unit
will be turned on.
It determines whether the heat generator integration is
Integration mode
activated at a fixed temperature or automatically by means of
the cost-effectiveness calculation.
If "Integration mode = MAN" is set, the outdoor temperature is
DHW activation temp.
established below which domestic hot water of the indoor unit
only is enabled.
If "Integration mode = MAN" is set, the outdoor temperature is
Heat. activation temp.
established below which central heating of the indoor unit only
is enabled.
Menu item
O.U. working parameters
O.U. Status
System State
Menu item
Flow temp.
Return temp.
Calc. sys. temp. set O.U.
Calc. DHW temp. set
Compress.outlet temp.
Cool.temp. on exch.
Evaporator temp.
External temperature
Compressor frequency
"Service" -> "Integration" menu
Description
"Service" -> "Generator info" menu
Submenu for the working data of the outdoor unit
Submenu for the operating status of the outdoor unit
Submenu for the operating status of the system
"Service" -> "Generator info" -> "O.U. working parameters" menu
Instant outlet temperature from the outdoor unit
Outdoor unit return temperature
Flow set point determined by the outdoor unit
DHW set point determined by the outdoor unit
Outdoor unit compressor temperature
Coolant temperature inside the plate heat exchanger
Evaporator temperature
External room temperature
Current compressor frequency
Range
Default
--
--
Yes / No
Yes
0 - 240 (5 minute
20'
steps)
0 - 240 (5 minute
20'
steps)
0 ÷ 15 °C
AUTO / MAN
MAN
-14 ÷ 35 °C
-14 ÷ 25 °C
Description
Description
Customised
value
3
0
0
91