Enable external probe
Defines the use of the external probe.
With the external probe not in use it defines the minimum flow
temperature that can be set by the user. With the external probe
Minimum flow set
enabled it defines the minimum flow temperature correspond-
ing to operation with maximum external temperature
Without the external probe it defines the maximum flow
temperature that can be set by the user. With the external probe
Maximum flow set
present it defines the maximum flow temperature correspond-
ing to operation with minimum external temperature
With the external probe enabled it defines at what external
Minimum external temp.
temperature the system must operate at the maximum flow
temperature
With the external probe present it defines at what maximum
Maximum external temp.
external temperature the system must operate at the minimum
flow temperature
It enables you to set operation of the control panel as ON/OFF or
modulating. Set "Yes", the flow temperature will be varied
depending on the room temperature set. Set "No", the flow
temperature will be kept constant until the desired room
Modul. with room probe
temperature is reached.
N.B.: if an outdoor temperature probe is enabled, the flow
temperature will be set depending on the relative functioning
curve.
It establishes the system reaction speed according to the type of
system present.
Example:
Inertia or dimension
5 system with little heat inertia
10 system with normal dimensions with radiators
20 system with a lot of heat inertia (e.g. floor-standing system)
Menu item
Enab. Heater kit
Enables operation of the heater kit
Reduction function
Enables a reduction of PdC noise.
O.U. antifreeze protect.
Indicate the presence of antifreeze fluid in the system
90
"Service" -> "Temperature control" menu
Description
"Service" -> "O.U. settings" menu
Description
Range
Default
Yes / No
Yes
25 ÷ 55
30
35 ÷ 80
50
-25 ÷ +15 °C
-5
-5 ÷ +45 °C
25
Yes / No
Yes
1 ÷ 20
10
Range
Default
Yes / No
No
No / Level 1 /
No
Level 2
Level 1 / Level 2 /
Level 3
Level 3
Customised
value
Customised
value