Programming - Immergas VICTRIX HYBRID PLUS Manual

Hide thumbs Also See for VICTRIX HYBRID PLUS:
Table of Contents

Advertisement

3.6
P.C.B. PROGRAMMING
By modifying these parameters as described below, the system can be adapted according to specific needs.
Access the "Service" menu by pressing the right "Menu" button and turning the main switch until selecting the desired menu. Press the
main switch to confirm the selection. Insert the relative access code and customise the parameters according to your requirements.
Menu item
System definition
Temperature control
O.U. settings
Integration
Generator info
Maintenance
Restore default settings
Menu item
Room control interf.
Establishes the temperature control device in use
The pump can function in two ways.
- Intermittent: in "winter" mode, the circulator is managed by
the
Pump operation
control panel or the room thermostat.
Continuous = in "Winter" mode the pump is always in
operation.
Min. pump speed
Minimum speed used value
Max. pump speed
Maximum speed used value
Pump Delta T
Temperature delta to be maintained
DHW hysteresis
Not used on this model
Enable room antifreeze
Enables the room antifreeze function
Allows to set the room temperature for activation of the
Room antifreeze temp.
anti-freeze function.
"Service" menu
Sub-menu to define the devices connected to the system
Temperature control setting sub-menu
Outdoor unit configuration submenu
System integration setting sub-menu
System information sub-menu
Activation of system maintenance functions
Allows to reset all parameters with factory values
"Service" -> "System definition" menu
Description
Description
Range
Rem.C. / RT
Inter. / Simul.
10 - 100 %
10 - 100 %
5 - 10
-
Yes / No
3 ÷ 10 °C
Range
-
-
-
-
-
-
Yes / No
Customised
Default
value
Rem.C.
Inter.
60 %
100%
5
-
Yes
5 °C
89