By varying the type of installation the classification of the appliance and precisely:
- Type B
or B
appliance if installed using the relevant terminals for air intake directly from the room in which the appliance
23
53
has been installed.
- Type C appliance if installed using concentric pipes or other types of pipes envisioned for the sealed chamber appliance for
intake of air and expulsion of flue gas.
The equipment classification is shown in the illustrations of the various installation solutions on the following pages.
Only a professionally enabled company is authorised to install Immergas appliances.
Installation must be carried out according to regulation standards, current legislation and in compliance with local technical
regulations and the required technical procedures.
It is forbidden to install appliances removed from other systems.
The manufacturer declines all liability in the event of damage caused by appliances removed from other systems or for any
non-conformities with such equipment.
Check the environmental operating conditions of all parts relevant to installation, referring to the values shown in the techni-
cal data table in this booklet.
Installation of the appliance when powered by LPG or propane air must comply with the rules
regarding gases with a greater density than air (remember, as an example, that it is prohibited
to install plants powered with the above-mentioned gas in rooms where the floor is at a lower
quota than the country level).
If installing a kit or servicing the appliance, always empty the system's circuit first so as not to compromise the appliance's elec-
trical safety (Parag. 2.15).
Always disconnect the appliance from voltage and, depending on the type of operation, decrease the pressure and/or bring it to
zero in the gas and DHW circuits (when combined with a Storage Tank Unit).
Before installing the appliance, ensure that it is delivered in perfect condition; if in doubt, contact the supplier immediately.
Packing materials (staples, nails, plastic bags, polystyrene foam, etc.) constitute a hazard and must be kept out of the reach of
children.
If the appliance is installed inside or between cabinets, ensure sufficient space for routine servicing; for minimum installation
distances, see Fig. 4.
It is just as important that the intake grids and exhaust terminals are not obstructed.
It is recommended to check that no flue gas recirculation is found in the air sample points
(0.5% maximum permitted CO
The minimum distance for exhaust pipes from flammable materials must be at least 25 cm.
Keep all combustible material away from the appliance (paper, rags, plastic, polystyrene, etc.).