Fault And Anomaly Signals - Immergas VICTRIX HYBRID PLUS Manual

Hide thumbs Also See for VICTRIX HYBRID PLUS:
Table of Contents

Advertisement

2.12 FAULT AND ANOMALY SIGNALS

ANOMALY IN PROGRESS
IMPOSTA DATA E ORA
I.U. communication error
Esc
IMPOSTA DATA E ORA
Historical alarm code
Historical Index:
Alarm code:
Alarm code n. xxx
at 15:07 on 25 Feb 2020
Esc
List of Indoor Unit Anomalies
Error
Anomaly signalled
Code
01
No ignition block
Safety thermostat
function block (NTC
02
flow/return
overheating)
Flue safety thermostat
03
block
Contacts resistance
04
block
Delivery probe fault
05
(1) If the block or anomaly persists, contact an authorised company (e.g. Immergas Authorised After-Sales Centre)
(2) The anomaly can only be verified in the list of errors in the "Information" menu
72
Back
1
xxx
Back
If room central heating or domestic hot water production is
requested, (when the boiler is paired with a storage tank
unit) the system does not switch on within the preset time.
Upon Victrix Hybrid Plus commissioning or after extend-
ed downtime, it may be necessary to eliminate the block.
During normal operation, if a fault causes excessive over-
heating internally, the system goes into overheating block.
During normal operation, if excessive flue gas overheating
occurs due to an anomaly, the system goes into lockout.
The P.C.B. detects a fault on the gas valve supply. Check its
connection. (the anomaly is detected and displayed only in
the event of a request).
The board detects an anomaly on the flow NTC probe.
The system signals any anomalies by displaying the attention
screen with the relative anomaly code (Fig. 50).
Press the "Exit" button to go back to the main screen and the
anomaly is displayed with the
50
You must access the "Anomalies log" menu to display the anoma-
lies log where the last 10 system anomalies are displayed in time
order (Fig.51). Turn the main switch to scroll through the list.
Within the "Anomalies log" menu it is also possible to delete the
list by selecting yes under "Delete history".
Errors relating to the indoor unit are also signalled on its panel.
51
Cause
symbol.
UI Status / Solution
Press the Reset button (1)
Press the Reset button (1)
Press the Reset button (1)
Press the Reset button (1)
The system does not start (1)

Advertisement

Table of Contents
loading

This manual is also suitable for:

3.030699

Table of Contents