2.8 SETTINGS MENU

Press the "Menu" button to access a list of variables that enable you to customise use of the system.
Set Point Zone
Set Point DHW
Time and Program
Generator management
Information
Esc
The list refers to the panel with firmware revision 2.01.
Hereunder is a list of available menus.
Menu item
Zone Set Point
DHW Set point
Clock and Programs
Generator management
Information
Anomalies log
Service
Language
Menu item
Heat. comfort set
Room temperature in central heating zone Comfort mode
Heat. economy set
Room temperature in central heating zone Economy mode
Flow set
Flow temperature in central heating mode
Offset temperature for central heating zone (only used with
Flow offset
operation with external probe)
Menu item
Domestic hot water temperature in Comfort phase (when
Comfort set
combined with a storage tank unit)
Domestic hot water temperature in Economy phase (when
Economy set
combined with a storage tank unit)
Disinfect
Activates domestic hot water disinfection mode (*)
(*) If "24h" is chosen, the function is activated every day at 02:00; if "7dd" is chosen, the function is activated every Monday at 02:00.
66
Menu
[ ... ]
[ ... ]
[ ... ]
[ ... ]
[ ... ]
Back
Defines the operating parameters to manage the zone
Defines the operating parameters in DHW mode (when combined with a storage tank unit)
Defines the date/time and time operating slots
Defines electricity and gas prices for choosing the generator to be used
Display system operating data
Displays the list of the last 10 anomalies
Password protected menu dedicated to a qualified technician
Defines the Control panel operation language
"Zone Set Point" menu.
Description
"DHW Set point" menu
Description
To browse the menus, which can be accessed by pressing the rela-
tive "RH" or "LH" context buttons, scroll through the sub-menus
displayed by turning the main switch.
Press the said selector to select the one highlighted.
By pressing repeatedly, you can scroll down the menu levels and
go back to a previous level by pressing the "Back" context button.
To exit the menu completely, press the "Exit" button, which will
take you back to the initial page of normal operation.
48
To confirm the parameter change, press the main switch.
MAIN MENU
Description
- 15 ÷ + 15°C
Off - 24h - 7dd
Range
Default
15 ÷ 35 °C
20
5 ÷ 25 °C
17
25 ÷ 80 °C
40
0
Range
Default
30 ÷ 60 °C
50
30 ÷ 45 °C
30
-
Customised
value
Customised
value