1.29 CONFIGURATION FOR C6 FLUE INSTALLATION

Appliance designed to be connected to a commercial exhaust/intake system.
Gas type
Flue temperature at maximum output
Flue gas mass at maximum power
Flue temperature at minimum output
Flue gas mass at minimum power
CO
at Q. max.
2
CO
a Q. minimum
2
Maximum head available at maximum power (maximum resistance
value of the commercial flue system)
Maximum head available at minimum power
Maximum temperature that the exhaust pipes can reach
- Ducts must withstand condensation (only for condensing models);
- Air intake ducts must withstand working air temperatures of up to 60°C;
- The maximum permissible percentage of flue gas recirculation in windy conditions is 10%.
- Suction and exhaust pipes cannot be installed on opposing walls;
- With flues in configuration C
discharge into pressurised flues is not permitted.
6
G20
°C
70
kg/h
38
°C
64
kg/h
8
%
9,7 (9,5 ÷ 10,2)
%
8,8 (8,5 ÷ 9,0)
Pa
150
Pa
4
°C
120
G31
69
37
69
7
11,4 (11,1 ÷ 11,5)
10,6 (10,5 ÷ 10,9)
150
4
120
51