Immergas VICTRIX HYBRID PLUS Manual page 43

Hide thumbs Also See for VICTRIX HYBRID PLUS:
Table of Contents

Advertisement

Vertical kit assembly with aluminium slate Ø80/125 (Fig. 28)
To install the kit Ø 80/125 one must use the flanged adapter kit (pos. 2, Fig. 24).
1. Install the concentric flange (2) on the flue exhaust of the appliance, positioning gasket (1) with the circular projections downwards in
contact with the appliance flange.
2. Tighten the concentric flange with the screws in the kit.
Imitation aluminium slate installation:
3. Tighten the concentric flange with the screws in the kit.
4. Replace the slates with the aluminium sheet (4), shaping it to ensure that rainwater runs off.
5. Position the fixed half-shell (5) on the aluminium slate;
6. Insert the intake-exhaust terminal (7);
7. Fit the Ø 80/125 concentric terminal pipe with the male side (smooth) to the female side of the adapter (1) (with lip seals) up to the end
stop, making sure that the wall sealing plate (3) has been fitted; this will ensure sealing and joining of the elements making up the kit.
7
6
5
4
3
2
1
Extensions for vertical kit Ø 80/125 (L = maximum length)
(Fig. 29).
The kit with this configuration can be extended to a max. straight
vertical length of 32 m, including the terminal. If additional com-
ponents are assembled, the length equivalent to the maximum al-
lowed must be subtracted. In this case specific extensions must be
requested.
The adaptor kit includes (Fig. 28):
C
33
N°1 Gasket (1)
N°1 Adapter Ø 80/125 (2)
The Ø 80/125 kit includes (Fig.28):
N°1 Wall sealing plate (3)
N°1 Aluminium slate (4)
N°1 Fixed half-shell (5)
N°1 Mobile half-shell (6)
N°1 Concentric intake/exhaust pipe Ø 80/125 (7)
The remaining kit components must not be used
28
C
33
29
43