Immergas VICTRIX HYBRID PLUS Manual page 39

Hide thumbs Also See for VICTRIX HYBRID PLUS:
Table of Contents

Advertisement

Horizontal intake/exhaust assembly kits Ø 60/100 (Fig. 22)
1. Install the curve with flange (2) on the central hole of the appliance, positioning gasket (1) with the circular projections downwards in
contact with the appliance flange, and tighten using the screws contained in the kit.
2. Fit the Ø 60/100 (3) concentric terminal pipe with the male side (smooth) to the female side of the bend (2) up to the end stop, making
sure that the internal and external wall sealing plates have been fitted; this will ensure sealing and joining of the elements making up
the kit.
2
1
3
Extensions for horizontal kit Ø 60/100 (L = maximum length) (Fig. 23).
The kit with this configuration can be extended up to a max. horizontal length of 12.9 m including the terminal with grid and excluding
the concentric bend leaving the appliance.
In this case the special extensions must be requested.
This configuration corresponds to a resistance factor of 100.
Immergas also provides a Ø 60/100 simplified terminal, which in combination with its extension kits allows you to reach a maximum
extension of 11.9 metres.
4
5
The kit includes (Fig. 22):
C
13
N°1 Gasket (1)
N°1 Concentric bend Ø 60/100 (2)
N°1 Int./exhaust concentric terminal Ø 60/100 (3)
N°1 Internal wall sealing plate (4)
N°1 External wall sealing plate (5)
22
L
C
13
23
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

3.030699

Table of Contents