Terminals 1 and 2 of the indoor unit are 230V/50Hz.
All Immergas chrono-thermostats are connected with 2 wires only.
Carefully read the user and assembly instructions contained in the accessory kit.
Disconnect power to the unit before making any electrical connections.
The chrono-thermostat allows:
- set two room temperature value: one for day (comfort temperature) and one for night (reduced temperature);
- set a weekly programme with four daily switch on and switch off times;
- selecting the required function mode from the various possible alternatives:
• manual mode (with adjustable temperature);
• automatic mode (with set programme);
• forced automatic operation (momentarily changing the temperature of the automatic program).
The chrono-thermostat is powered by two 1.5V LR 6 type alkaline batteries.

1.17 230 VAC CONFIGURABLE OUTLET

A configurable relay is available on the P.C.B. of the indoor unit, its outlet is available on terminals 5 and 6 (to disassemble the cover to
access the connections compartment of the control panel refer to Par.1.12.
The configurations that can be set for parameter "P3" are listed in the P.C.B. programming paragraph.
29