Electrical connection diagram Victrix Hybrid Plus
Key (Fig. 13):
A23 - Audax.DK4 Outdoor Unit
A33 - Victrix Hybrid control panel
B2
- Storage tank probe (optional - not available for this model)
B9
- DHW inlet probe (optional - not available for this model)
A 230VAC (optional) room thermostat can be connected on terminals 1 and 2 of the terminal block present in the indoor unit. For the
connection, see 1.16.
To connect the Audax.DK4 outdoor unit to the control panel, connect the communication cables from terminals "D+ - D-" of the outdoor
unit to terminals "5 - 6 "of the control panel. Consult the relative instructions manual to access the electrical connections of the outdoor
unit.
To connect the communication BUS of the outdoor unit to the control panel, connect the communication cables from terminals "44 - 41"
of the indoor unit to terminals "1 - 2" of the control panel.
For low voltage power supply of the control panel, connect the communication cables from terminals "24-25" present on the terminal
block of the indoor unit to terminals "7-8" of the control panel.
To connect the optional DHW input probe, connect the cables to terminals "38 - 48" on the terminal board of the indoor unit.

1.13 CONTROL PANEL MAIN DIMENSIONS

S20-230VAC - Domestic hot water inlet probe (optional)
X
- Power supply
Y
- Configurable relay
Z
- Configurable output
13
14
27