The plugs (standard supply) that come with the appliance are only to be used to fix the latter to the wall; they only ensure adequate support
if inserted correctly (according to technical standards) in walls made of solid or semi-hollow brick or block. In the case of walls made
from hollow brick or block, partitions with limited static properties, or in any case walls other than those indicated, a static test must be
carried out to ensure adequate mount. Appliances must be installed in such a way as to avoid knocks or tampering.
Wall mounting of the appliance must guarantee stable and efficient support for the generator.
These appliances are used to heat water to below boiling temperature in atmospheric pressure.
They must be connected to a central heating system and domestic hot water circuit (when combined to a storage tank unit) suit-
ed to their performance and capacity.
Risk of damage due to corrosion caused by unsuitable combustion air and environment.
Spray, solvents, chlorine-based detergents, paints, glue, ammonium compounds, powders and similar cause product and flue
duct corrosion.
Check that combustion air power supply is free from chlorine, sulphur, powders, etc.
Make sure that no chemical substances are stored in the place of installation.
If you want to install the product in beauty salons, paint workshops, carpenter's shop, cleaning companies or similar, choose a
separate installation area that ensures combustion air supply that is free from chemical substances.
Make sure the combustion air is not fed through chimneys that were previously used with boilers or other central heating appli-
ances powered by liquid or solid fuels. In fact, these may cause an accumulation of soot in the chimney
The Storage Tank Unit must also be installed in an environment in which the temperature cannot fall below 0°C.
"Disinfection" heat treatment of the Immergas storage tank unit (can be activated by a special function on the control panel):
During this phase, the temperature of the water inside the tank exceeds 60°C with the subsequent risk of burns.
Keep this domestic hot water treatment under control (and inform users) (when combined with a storage tank unit) to avoid
unpredictable damage to people, animals, property.
If required install a thermostatic valve on the domestic hot water outlet to prevent scalding.
Risk of material damage after using sprays and liquids to search for leaks
Leak sprays and liquids clog the reference hole P1. Ref. (Fig. 55) of the gas valve, damaging it irreparably.
During installation and maintenance, do not use spray or liquids in the upper area of the gas valve (electric connections side).