Information Menu - Immergas VICTRIX EXA 24 X 1 ERP Instruction Booklet And Warning

Table of Contents

Advertisement

2.6 INFORMATION MENU.

By pressing the "Info" button (4), the "Information menu" is
activated for at least 1 second, displaying some boiler operating
parameters.
Press the "Info" button (4) to scroll the various parameters.
To exit the menu, press the "Info" button (4) up to the end of
the list, or by pressing the "Reset" button (3) or by waiting for
15 minutes.
With the menu active, the indicator (14) will alternately show
the indication of the parameter via the letter "d" plus the num-
ber of the parameter that is being displayed and the value of the
parameter itself.
Id
Parameter
d1
Displays the flame signal (uA x 10 approximate)
d2
Displays the primary exchanger output instant heating flow temperature
d3
Displays the storage tank unit temperature.
d4
Displays the values set for central heating set
d5
Displays the values set for DHW set
Displays the external temperature (if external probe present)
d6
If the temperature is below zero, the value is displayed flashing
d7
Not available
d8
Return probe temperature
Displays the list of the last five anomalies
d9
(To scroll the list, turn the CH temperature selector (6))
44
Description

Advertisement

Table of Contents
loading

Table of Contents