Immergas VICTRIX EXTRA 12 PLUS Instructions And Recommendations page 98

Table of Contents

Advertisement

Victrix Extra 35 Plus
Id
Parameter
Parameter
G.
Gas type
n.
Boiler model
Minimum no. of
S.0
fan revs
Maximum no. of
S.1
fan revs
Ignition phase
S.2
no. of fan revs
F.0
Flue length
Presence of
clapet valve on
F.1
flue gas (C
(10)
C
)
(12)
* : 0 cannot be used; from 4 to 20 cannot be used; only 1-2-3 available.
If parameters are changed, the anomalies "E62" or "E72" will appear and automatic calibration will be required.
98
Description
Display gas type: nG (Methane) or LG (LPG)
Define the boiler model
Defines the operating speed of the fan at minimum output
Defines the operating speed of the fan at maximum output
Defines the operating speed of the fan during the ignition
phase
Defines the length of the flue (Parag. 3.12)
If present, automatic corrections are made to the fan's
-
operating range
Range
Default
nG-LG-AP
nG
0-20*
1
700-3000
2200
2000-8300
7200
2000-4500
3800
0-2
0
0-1
0
Customised
value

Advertisement

Table of Contents
loading