Programming - Immergas VICTRIX EXTRA 12 PLUS Instructions And Recommendations

Table of Contents

Advertisement

3.13 P.C.B. PROGRAMMING
The device is prepared for possible programming of several operation parameters.
By modifying these parameters as described below, the device can be adapted according to specific needs.
+
-
RESET
INFO
+
-
RESET
INFO
+
-
RESET
INFO
+
-
RESET
INFO
+
-
MODE
67
+
-
MODE
68
+
-
MODE
69
+
-
MODE
70
To access the programming phase, press and hold the "MODE"
and "RESET" buttons for more than 5 seconds; the display shows
two dashes "-" single blinks and you must enter the password (69)
to access the programming menus.
To enter the digit on the left, use the +/- buttons (5-6) to adjust the
DHW temperature (
); to enter the digit on the right, use the +/-
buttons (7-8) to adjust the central heating temperature (
Press MODE to confirm the password.
Once you have entered the menu, the family of parameters is dis-
played.
Press "INFO" to scroll the list of parameter families.
Scrolling though the list of parameter families occurs in a circular
mode: G→P→t→A→G→P→...
Once you have selected the required family (E.g. t), press "MODE"
to confirm and enter in the family.
Once you have entered in the family, press "INFO" to scroll the list
of parameters and select the required one (E.g. t.13). Then press
"MODE" to confirm and view the value.
).