RESET
INFO
When the new flame set is reached, the symbol (
digit. It is possible to move on to the next stage by pressing the MODE button or to make a further correction by decreasing or increasing
the flame set value by a further unit (up to a maximum of -5 - +5) in the same way.
The procedure will end either automatically at the end of the maximum time or by pressing the MODE button on completion of the last
calibration step (Mi) with digit flashing to confirm successful calibration.
To exit early, press the RESET button.
+
-
MODE
66
) will become steady again and the previously set value will be displayed on the right
You may then:
- proceed to the next calibration step by pressing MODE;
- (ONLY IF NECESSARY) change the value of the flame set to
correct the CO
value. (Increase the flame set value to decrease
2
the CO
value). Press the +/- buttons (7-8) to adjust the heating
2
temperature (
) by selecting a value between -1, 0 and 1 (the
edited value will flash). Confirm the value by pressing the
MODE button (the symbol
cation (MA, AC, Mi) of the current phase alternating with the
flow temperature will appear again on the right digit).
will start flashing and the indi-