Calibration Type Involving The Replacement Of A Component - Immergas VICTRIX EXTRA 12 PLUS Instructions And Recommendations

Table of Contents

Advertisement

3.9

CALIBRATION TYPE INVOLVING THE REPLACEMENT OF A COMPONENT.

When performing extraordinary maintenance on the appliance, involving the replacement of a component, such as the P.C.B. (if the re-
movable memory is not put into the replacement board) or components in the air, gas and flame control circuits, the appliance will need
to be calibrated.
Select the type of calibration to be carried out according to the table below.
Component replaced
Gas valve
Fan
Burner
Ignition / detection electrode
P.C.B. (New virgin P.C.B. without removable memory recovery)
P.C.B. (Recovery of the removable memory with the boiler parameters
set from the replaced board)
88
Type of calibration required
Automatic calibration
Automatic calibration
1 Automatic calibration
2 Possible manual calibration with verification of CO
1 Automatic calibration
2 Possible manual calibration with verification of CO
Reset the parameters
1 Automatic calibration
2 Possible manual calibration with verification of CO
No calibration required.
values
2
values
2
values
2

Advertisement

Table of Contents
loading

Table of Contents