Immergas VICTRIX EXTRA 12 PLUS Instructions And Recommendations page 73

Table of Contents

Advertisement

Error
Anomaly signalled
Code
OFF MODE set on
boiler (fault only
83
displayed on remote
device)
Combustion anomaly
(Power reduction in
84
progress)
Block - gas valve
87
control
Block - gas valve
88
control
Combustion signal
89
unstable
Combustion signal
90
beyond limit
Incorrect ignition
91
block
Fan revs correction
92
limit
Combustion signal
93
beyond limit
94
Combustion anomaly
Combustion signal
95
discontinuous
(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised Service Centre)
(2) The anomaly can only be verified in the list of errors in the "Information" menu
(3) Error displayed only on CAR
(4) Error displayed only on Anomalies log
The boiler is set to OFF mode. Commands sent from the re-
mote device are not executed.
A low supply pressure is detected on the gas line. As a result
the appliance power is limited and the anomaly is reported.
A malfunction of one of the components that controls the
gas valve has been detected.
A malfunction of one of the components that controls the
gas valve has been detected.
The flame is unstable due to: presence of flue gas recircula-
tion, wind, unstable gas pressure, unstable fan speed, or
due to system malfunction.
The combustion signal is beyond the adjustment range re-
quired for an extended period of time.
The board has exhausted all possible actions in order to ob-
tain optimal ignition of the burner.
The system has exhausted all possible corrections of the
number of fan revs.
The combustion signal is beyond the adjustment range re-
quired for a limited period of time.
A problem is detected on the combustion control, which
may be due to: gas low pressure, flue recirculation, defective
gas valve or P.C.B.
The system detects a discontinuous combustion signal.
V2
Cause
Appliance status / Solution
Reactivate all boiler functions by
pressing the ON/Stand-by button.
If normal conditions are restored, the
appliance restarts without having to
be reset (1). (1) (2) (4)
The appliance does not start (1)
The appliance does not start (1)
The appliance keeps working (1) (2) (4)
The appliance keeps working (1) (2) (4)
Press the Reset button (1)
The appliance keeps working (1) (2) (4)
The appliance keeps working (1) (2) (4)
If normal conditions are restored, the
appliance restarts without having to
be reset (1). (1) (2) (4)
The appliance keeps working (1) (2)
73