Before mounting it, ensure that the gaskets are in the correct position.
In the event component lubrication (already carried out by the manufacturer) is not sufficient, remove the residual lubricant
using a dry cloth, then to ease fitting coat the parts with common or industrial talc.
7. Mount the cover (A) complete with adaptor (1) and caps (6) on the wall.
8. Assemble the flue to the collective flue exhaust system.
9. Go to the display and through the path Menu/General settings/Menu access level, upon request "Enter password", enter the code 1122
(using knobs "Set DHW" and " Set CH") and press "Ok" after which, the "Menu access level" menu will open, where you will need to
select the type of access: "Service".
10. Set parameter F.1 = 1.
11. Perform the automatic calibration procedure (Parag.3.10).
Once all components have been assembled properly, the exhaust flue gas will be expelled in the collective flue, the combustion air for
normal appliance operation will be aspirated directly by the shaft (Fig. 30).
10
11
12
13
14
15
,
C
2
1
3
3
4
5
6
7
Key (Fig. 34):
The C
adaptor kit includes:
(10)
1
Door adaptor Ø 100 or Ø 125 (1)
A
No.1 Door gasket made of neoprene (2)
9
No.4 Screws 4.2 x 9 ST (3)
No.1 Hex headed screw M6 x 20 (4)
8
No.1 Flat nylon washer M6 (5)
No.2 Door hole closure metal-sheet plate plug (6)
No.1 Plug gasket made of neoprene (7)
No.1 Toothed washer M6 (8)
No.1 M6 nut (9)
6
The Ø 80/125 extension pipe kit includes:
1
Extension pipe unit Ø 80/125 (10)
The bend kit Ø 80/125 includes:
1
Concentric bend Ø 80/125 at 87° (11)
The non-return valve kit on the flues Ø 80 (12) includes:
1
Gasket Ø 80
1
Non-return valve on flues Ø 80
1
Extension Ø 125
1
Spacer Ø 80 th. 5 mm (to be excluded for this configuration)
No.1 Information sticker
The adaptor kit includes:
4
(kit Ø 80/125) M4 hex headed screws x 16 slotted screwdriver (13)
1
(kit Ø 80/125) Flanged adapter Ø 80/125 (14)
1
(kit Ø 80/125) Concentric gasket (15)
Supplied separately (Fig. 34):
34
No.1 Ducting kit door (A)
Key (Fig. 33):
C
10
C
- Minimum slope 5%
33
45