Technical Data; Variable Heat Output - Immergas VICTRIX EXTRA 12 PLUS Instructions And Recommendations

Table of Contents

Advertisement

4

TECHNICAL DATA

4.1

VARIABLE HEAT OUTPUT

The power data in the table has been obtained with intake-exhaust pipe measuring 0.5 m in length. Gas flow rates refer to net
calorific value below a temperature of 15°C and at a pressure of 1013 mbar.
Victrix Extra 12 Plus
FLOW RATE
HEAT
OUTPUT
OUTPUT
(kW)
(kW)
12,2
12,0
11,5
11,3
11,0
10,8
10,5
10,3
9,5
9,3
9,0
8,9
8,5
8,4
7,5
7,4
7,1
7,0
6,5
6,4
6,0
5,9
5,0
4,9
4,5
4,4
4,0
3,9
3,5
3,4
2,8
2,7
2,0
1,9
120
METHANE
(G20)
FAN REVS
MODULATION
(rpm)
(%)
3525
39
3400
36
3300
34
3225
33
3025
29
2925
27
2850
25
2650
21
2600
20
2475
17
2375
15
2200
11
2100
9
2025
8
1925
6
1800
3
1650
0
GAS FLOW
RATE
FAN REVS
BURNER
(m
/h)
(rpm)
3
1,29
3400
1,22
3325
1,16
3250
1,11
3200
1,01
3075
0,95
3025
0,90
2975
0,79
2850
0,75
2800
0,69
2725
0,63
2675
0,53
2550
0,48
2500
0,42
2450
0,37
2375
0,30
2300
0,21
-
PROPANE
(G31)
GAS FLOW
MODULATION
RATE
BURNER
(%)
(kg/h)
30
0,95
28
0,89
26
0,85
25
0,82
21
0,74
20
0,70
18
0,66
15
0,58
14
0,55
12
0,50
10
0,47
7
0,39
6
0,35
4
0,31
2
0,27
0
0,22
-
-