Immergas VICTRIX EXTRA 12 PLUS Instructions And Recommendations page 102

Table of Contents

Advertisement

List of t family parameters.
To enter in the parameters of the family t, press "MODE" with t on the display. "t." will appear.
Press "INFO" to scroll the submenus of the t family.
Id
Parameter
Parameter
Central heating
set point
t.0
minimum
temperature
Central heating
set point
t.1
maximum
temperature
Boost Mode
(DHW
t.2
Recirculation
Function Par.
2.4)
Solar Delay
t.3
timing
Domestic hot
t.4
water priority
timer
Central heating
t.5
ignitions timer
Heating ramp
t.6
timing
Heating
switch-on delay
request from
t.7
room thermo-
stat or remote
control
t.8
Display lighting
102
Description
Set minimum central heating / C.H. set limit available
Set maximum central heating / C.H. set limit available
0: Always off
1: Always ON
2: Auto
Not used
Not used
The boiler has an electronic timer, which prevents the burner
from igniting too often in central heating mode.
In central heating mode, the boiler performs an ignition
ramp in order to reach the maximum output set.
The boiler is set to switch-on immediately after a request.
In the event of particular systems (e.g. area systems with
motorised thermostatic valves etc.) it may be necessary to
delay ignition.
Establishes the display lighting mode.
0: the display lights up during use and lowers after 15 seconds
of inactivity. In the case of anomaly the display remains at
maximum lighting.
1: display lighting always low.
2: display lighting always high.
Range
Default
20..(t.1-5)
20
(20-50)
(t.0+5)..85
85
(25-85)
-
-
-
-
-
-
0-600 seconds
180
0-840 seconds
180
0-600 seconds
0
0-2
0
Value
customized

Advertisement

Table of Contents
loading

Table of Contents